BURNDY YGA29-2N Hylug Grounding 2 Hole

Burndy YGA29-2N Hylug Grounding Irreversible Compression Terminal, 250 kcmil Copper Conductor Size, 1.09″ Width, 5.16″ Length

Burndy; Compression Terminal; HYGROUND, HYLUG; YGA, Grounding Irreversible; Cable Size: 250 KCMIL Stranded Copper; Stud Size: 1/2 IN Hole; Number Of Holes: 2; Material: Copper; Tools, Die Set Catalog Number, And (number Of Crimps): Mechanical: MD7-34R, OUR840 Tool, W29VT Die, (4); Hydraulic: Y35/Y39/Y45/PAT750/Y46/Y750 Tool, U29RT Die, (2); Stud Hole (spacing): 1-3/4 IN; Die Index: 16 Element A

Application : For Grounding Applications And Direct Burial In Earth Or Concrete

Brand Name : Burndy

Material : Copper

Standard : UL467, UL486A Listed, CSA Certified, RoHS Compatible

Sub Brand : HYGROUND, HYLUG

Type : YGA, Grounding Irreversible

special features : Features: Irreversible Compression HYLUG Ground Terminal Specifically Designed For Grounding Applications; Each Connector Has An Inspection Probe Hole To Ensure Proper Cable Insertion; UL 467 Listed; Acceptable For Direct Burial In Earth Or Concrete; UL486A Listed; Prefilled With Penetrox Compound And Strip Sealed; Tools, Die Set Catalog Number, And (number Of Crimps): Mechanical: MD7-34R, OUR840 Tool, W29VT Die, (4); Hydraulic: Y35/Y39/Y45/PAT750/Y46/Y750 Tool, U29RT Die, (2); Stud Hole (spacing): 1-3/4 IN; Die Index: 16 Element A

DETAIL SPESIFICATION

Burndy YGA292N Hylug™ Compression Grounding Terminal; 2 Hole, 1/2 Inch Stud, 250 KCMIL Stranded Copper

Product Details
Dimension: 5.210 Inch Length x 1.090 Inch Width
Index number 16

Burndy Hylug™ 2-Hole compression grounding terminal is made of copper for high conductivity. It has a stud of size 1/2 Inch and 1-11/16-Inch long strip. It can accommodate copper stranded wires of size 250 KCMIL. It measures 5.210 Inch x 1.090 Inch. Hylug is RoHS compliant, UL listed and CSA certified.

Product Specifications
Application For Grounding Applications And Direct Burial In Earth Or Concrete
Barrel Size 0.750 Inch OD
Brand Name Hubbell Electrical / Burndy
Conductor Range 250 KCMIL Stranded Copper
Conductor Size 250 KCMIL Stranded Copper
Dimension 5.210 Inch Length x 1.090 Inch Width
Finish Unplated
Item Compression Grounding Terminal
Material Copper
Mfr/Vendor Hubbell Electrical / Burndy
Number of Holes 2
Order Minimum 1
Overall Length 5.210
ShortDescriptionStripped Hubbell-Electrical-Burndy-YGA292N-Hylug
Special Features Features: Irreversible Compression HYLUG Ground Terminal Specifically Designed For Grounding Applications; Each Connector Has An Inspection Probe Hole To Ensure Proper Cable Insertion; UL 467 Listed; Acceptable For Direct Burial In Earth Or Concrete; UL486A Listed; Prefilled With Penetrox Compound And Strip Sealed; Tools, Die Set Catalog Number, And (number Of Crimps): Mechanical: MD7-34R, OUR840 Tool, W29VT Die, (4); Hydraulic: Y35/Y39/Y45/PAT750/Y46/Y750 Tool, U29RT Die, (2); Stud Hole (spacing): 1-3/4 IN; Die Index: 16 Element A
Standard UL467, UL486A Listed, CSA Certified, RoHS Compatible
Standards Rated For Direct Burial, UL Listed, CSA Certified, RoHS Compliant, UL467
Strip Length 1-11/16
Stud Size 1/2
Sub Brand Hylug™
Tongue Size 3 Inch Length x 1.090 Inch Width x 0.160 Inch Thickness
Type Irreversible
UPC 781810220337
description Hubbell Electrical / Burndy Hylug™ 2-Hole compression grounding terminal is made of copper for high conductivity. It has a stud of size 1/2 Inch and 1-11/16-Inch long strip. It can accommodate copper stranded wires of size 250 KCMIL. It measures 5.210 Inch x 1.090 Inch. Hylug is RoHS compliant, UL listed and CSA certified.
feature#1 Dimension: 5.210 Inch Length x 1.090 Inch Width
feature#2 Index number 16

 

 

BURNDY YGA2C-2N Hylug 2 STR

Burndy YGA2C-2N Hylug Grounding Irreversible Compression Terminal, 2 str. Copper Conductor Size, 0.81″ Width, 4.71″ Length

Product Description

 


Product Features

  • Grounding irreversible compression terminals
  • Designed for grounding applications
  • Each connector has an inspection probe hole to ensure proper cable insertion
  • UL467 listed
  • Acceptable for direct burial in earth or concrete

Dimensional

General

Conductor(s)

Physical

Approvals / Certifications

Other Features

Dimensional
 Thickness 0.12
 B Length (in) 1.22
 Pad Width (in) 0.83
 Stud Size (Fraction) 1/2
 E – in 1.75
 Strip Length 1-5/16
General
 Product Description Hylug Copper ground, 2 str., 4.71 in L, Grounding Irreversible Compression Terminals
Conductor(s)
 Copper Solid Size (Range) N/A
 Copper Stranded (Range) 2 Str.
Physical
 Type of Plating Unplated
 Connector Type Terminal
 Plated (Yes or No) N
 Index Number 10
 Product Material Copper
Approvals / Certifications
 Rated for Direct Burial Y
 UL Listed Y
 CSA Certified Y
 ROHS Compatible Compliant
 UL Recognized N
 CULUS N
 Industry Standards UL467

 

 

CMP E1FW M32 Cable Gland

CMP CABLE GLAND

Available : CMP 32-E-FX-Z

Type: EExd IIC / EExd II BAS

Ex94c1293U  1″ – NPT
CMP Products is a leading specialist manufacturer of Cable Glands, Cable Connectors and associated accessories, used extensively for power, control, lighting and instrumentation cable applications in connection with IEC, NEC & CEC cables.

Having the widest portfolio of Cable Gland products to meet every kind of environment, CMP offers a variety of solutions for use in Marine, Explosive and Non Explosive (Industrial) Atmospheres, for a large selection of cable types.

The product search page of the website includes a number of the typical industry standard cable types found around the world that CMP cable glands can be associated with.

CMP design and produce Cable Glands with Ex d/Ex e Zone 1, Zone 2, Zone 21 & Zone 22 Approvals for use in Gas Group IIC environments under CENELEC & IEC Area Classification rules. Additionally Cable Connectors for NEC & CEC Classified Explosive Atmospheres Locations, are available for Class I, II & III, Divisions 1 & 2, where Gas Groups A, B, C, D and Dust Groups E, F & G are present.

International Explosive Atmospheres Approvals are held from Atex, IECEx, CEPEL/Inmetro, CSA, cCSAus, UL, GOST, EAC, NEPSI, TUV, and CIDET.

 

In addition Marine Classification Society Approvals from Lloyds, DNV & ABS are also held.

 

E1FW Tri-Star Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR Cable Gland

 

CMP Type E1FW Tri-Star Triple Certified Flameproof (Type “d”), Increased Safety (Type “e”) and Restricted Breathing (Type “nR”) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Explosive Atmospheres with Single Wire Armour (SWA) cable.

All CMP Cable Glands are EMC Tested.
E1FW ILL

Note: Deluge Proof version available, ferrule colour coded “white” for ease of identification

 

E1FW Cable Gland Table

Cable Gland Size Available Entry Threads ‘C’ Minimum Thread length ‘E’ Cable Bedding Diameter ‘A’ Overall Cable Diameter ‘B’ Armour Wire Diameter Across Flats ‘D’ Across Corners ‘D’ Nominal Protrusion Length ‘F’ Ordering Reference (Brass Metric) # PVC Shroud Reference* Cable Gland Weight (Kgs)
Standard Option Min Max Min Max Min Max Max Max
Metric NPT NPT2
20S/16 M20 1/2″ 3/4″ 15.0 3.1 8.6 6.1 13.2 0.80 1.25 24.0 26.4 58.5 20S16E1FW1RA PVC04 0.157
20S M20 1/2″ 3/4″ 15.0 6.1 11.6 9.5 15.9 0.80 1.25 24.0 26.4 58.5 20SE1FW1RA PVC04 0.157
20 M20 1/2″ 3/4″ 15.0 6.5 13.9 12.5 20.9 0.80 1.25 30.5 33.6 60.5 20E1FW1RA PVC06 0.206
25S M25 3/4″ 1″ 15.0 11.1 19.9 14.0 22.0 1.25 1.60 37.5 41.3 67.5 25SE1FW1RA PVC09 0.325
25 M25 3/4″ 1″ 15.0 11.1 19.9 18.2 26.2 1.25 1.60 37.5 41.3 67.5 25E1FW1RA PVC09 0.325
32 M32 1″ 1-1/4″ 15.0 17.0 26.2 23.7 33.9 1.60 2.00 46.0 50.6 69.5 32E1FW1RA PVC11 0.452
40 M40 1-1/4″ 1-1/2″ 15.0 22.0 32.1 27.9 40.4 1.60 2.00 55.0 60.5 78.0 40E1FW1RA PVC15 0.657
50S M50 1-1/2″ 2″ 15.0 29.5 38.1 35.2 46.7 2.00 2.50 60.0 66.0 75.5 50SE1FW1RA PVC18 0.734
50 M50 2″ 2-1/2″ 15.0 35.6 44.0 40.4 53.1 2.00 2.50 70.0 77.0 80.5 50E1FW1RA PVC21 0.748
63S M63 2″ 2-1/2″ 15.0 40.1 49.9 45.6 59.4 2.00 2.50 75.0 82.5 91.5 63SE1FW1RA PVC23 1.337
63 M63 2-1/2″ 3″ 15.0 47.2 55.9 54.6 65.9 2.00 2.50 80.0 88.0 92.0 63E1FW1RA PVC25 1.436
75S M75 2-1/2″ 3″ 15.0 52.8 61.9 59.0 72.1 2.00 2.50 89.0 97.9 99.0 75SE1FW1RA PVC28 2.073
75 M75 3″ 3-1/2″ 15.0 59.1 67.9 66.7 78.5 2.50 3.00 99.0 108.9 102.0 75E1FW1RA PVC30 2.622
90 M90 3″ 4″ 24.0 66.6 79.9 76.2 90.4 3.15 4.00 114.0 125.4 120.0 90E1FW1RA PVC32 4.174
100 M100 4″ 5″ 24.0 76.0 90.9 86.1 101.5 3.15 4.00 123.0 135.3 148.0 100E1FW1RA LSF33 4.523
115 M115 4″ 5″ 24.0 86.0 97.9 101.5 110.3 3.15 4.00 133.4 146.7 169.0 115E1FW1RA LSF34 6.860
130 M130 5″ 6″ 24.0 97.0 114.9 114.2 123.3 3.15 4.00 146.1 160.7 183.0 130E1FW1RA LSF35 8.121
Dimensions are displayed in millimetres unless otherwise stated

NOTE: *CMP SOLO LSF Halogen Free Shrouds also available on request. + Alternative armour clamping range available for non-standard armour sizes. # Other thread forms, materials and finishes are available. IEC Ex, ATEX & CSAus Explosive Atmosphere certification marking included as standard.

# IP66 as standard, IP67/IP68 available on request. Deluge Proof when fitted with optional CMP O-ring in the cable gland body joint.

Note: Ingress Protection and Deluge Protection are essentially different and should not be confused with each other.

Technical Data
Type E1FW Tri-Star
Design Specification EN 50262, BS 6121: Part 1:1989, IEC 62444
Mechanical Classifications Impact = Level 8, retention = Class B (EN 50262) Class D (IEC 62444)
Electrical Classifications Category B
ATEX Certificate SIRA13ATEX1071X, SIRA13ATEX4077X
Code of Protection Ex II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da, Ex II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb
Compliance Standards EN 60079-0,1,7,15,31
IEC Ex Certificate IECEx SIR 13.0026X
Code of Protection Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
Compliance Standards IEC 60079-0,1,7,15,31
cCSAus Certificate 1310517
Code of Protection Ex d IIC; Ex e II; Ex nR II; Class I, Div 2, Groups A,B,C,D; Class II, Div 2 Groups E,F,G; Class III; Encl Type T4X Class I, Zone 1, AEx e II / AEx nR II
Compliance Standards CAN/CSA-C22.2 No 0,18,25,30,174,94, CAN/CSA-E60079-0,1,7; ANSI/UL 514B Ed 5; ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4; UL60079-0,1,7
EAC Certificate (Previously GOST R & GOST K) TC RU C-GB.ГБ.05.B.00138
Code of Protection Ex 1 Ex d IIC Gb X, 1 Ex e IIC Gb X, 2 Ex nR IIC Gc X, Ex ta IIIC Da X
NEPSI Certificate GYJ13.1140X
Code of Protection Ex d IIC Gb / Ex e IIC Gb / DIP A21 TA
Compliance Standards GB3836.1/2/3, GB12476.1
INMETRO Approval TÜV 12.0618X
Code of Protection Exd II C Gb / Exe II C Gb, IP66W
Compliance Standards ABNT NBR IEC 60079-0,1,7 ANBT NBR IEC 60529:2005
RETIE Approval No. 03866
Marine Approvals LRS: 01/00172, DNV: E-10496, ABS: 01-LD234401A/3-PDA, RMRS: 011-6.11.4-5149
Continuous Operating Temperature -60°C to +130°C, (-20°C to +200°C with optional high temperature seal)
Ingress Protection Rating IP66 (Standard), IP67 & IP68 option available on request
Deluge Protection DTS01:91 option available on request
EMC Test Information SGS report 444 to EN55022
Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal Material CMP SOLO LSF Thermoset Elastomer
Cable Type(s) Single Wire Armour (SWA), Aluminium Wire Armour (AWA)
Armour Clamping Detachable Armour Cone & AnyWay Universal Clamping Ring
Sealing Technique CMP Inner Displacement Seal & Unique CMP “LRS” TM Outer Load Retention Seal
Sealing Area(s) Cable Inner Bedding & Outer Cable Sheath
Accessories Adaptor/Reducer, Earth Tag, Locknut, Serrated Washer, Entry Thread Seal, Shroud

 

 

2″ Sanitary Butt Weld 3 Pieces Ball Valve

3piece BALL VALVE

SS316, 3 Piece Sanitary Butt Weld Ball Valve

Connection Form:Welding
Channel:Straight Through Type
Structure:Floating Ball Valve
Type:Floating Ball Valve
Material:Stainless Steel or wcb

Product Description

Name: 3 piece weld end ball valve
Size: 1/4″–4″(DN8–DN100)
Material: Ss304(CF8), ss316(CF8M) ss201, WCB, and so on.
Nominal pressure: 1000WOG.
Suitable temperature: -40–300 centigrade degree.
End connection: Butt weld (weld type: Butt weld/socket weld).
Type of port: Full port. Seat: RPTFE, PTFE, PPL, etc.

3″ Conduit Elbow Normal Bend

normal bend

 

ELBOW NORMAL BEND 3″ RIDGID CONDUIT

FINISHING: HOT DIP GALVANIZED

Rigid Metal Conduit (RMC) – Steel Elbows

Rigid Metal Conduit (RMC) Steel Elbows Conforms With:

  • ANSI – American National Standard for Electrical Rigid Steel Conduit (ERSC) ANSI, C80.1
  • UL Standard for Electrical Rigid Metal Conduit – Steel, UL 6
  • National Electrical Code 2008 Article 344
  • Federal Inspection WW-C-581 (Class 1 Type A)
  • ANSI/ASME B.1.20.1-1983, Standard for Pipe Threads, General Purpose (Inch)
  • Rigid Metal Conduit Elbows are Hot-Dip Glvanized

Rigid Metal Conduit (RMC) Steel Elbows:

  • Permitted under all atmospheric conditions and occupancies
  • Shall be permitted to be installed in concrete, in direct contact with the earth
  • Permitted in areas of severe corrosive influences where protected by corrosion protection and judged suitable for the condition
  • Permitted in or under cinder fill where subject to permanent moisture when protected on all sides by a layer of noncinder concrete no less than 2 in. (50 mm) thick or with corrosion protection judged suitable for the condition
  • May be used with Aluminum fitting and enclosures

3″ Conduit Elbow Long Radius

LONG RADIUS ELBOW

ELBOW LONG RADIUS 3″ RIDGID CONDUIT

FINISHING: HOT DIP GALVANIZED

Rigid Metal Conduit (RMC) – Steel Elbows

Rigid Metal Conduit (RMC) Steel Elbows Conforms With:

  • ANSI – American National Standard for Electrical Rigid Steel Conduit (ERSC) ANSI, C80.1
  • UL Standard for Electrical Rigid Metal Conduit – Steel, UL 6
  • National Electrical Code 2008 Article 344
  • Federal Inspection WW-C-581 (Class 1 Type A)
  • ANSI/ASME B.1.20.1-1983, Standard for Pipe Threads, General Purpose (Inch)
  • Rigid Metal Conduit Elbows are Hot-Dip Glvanized

Rigid Metal Conduit (RMC) Steel Elbows:

  • Permitted under all atmospheric conditions and occupancies
  • Shall be permitted to be installed in concrete, in direct contact with the earth
  • Permitted in areas of severe corrosive influences where protected by corrosion protection and judged suitable for the condition
  • Permitted in or under cinder fill where subject to permanent moisture when protected on all sides by a layer of noncinder concrete no less than 2 in. (50 mm) thick or with corrosion protection judged suitable for the condition
  • May be used with Aluminum fitting and enclosures

3″ Channel Conduit Clamp

unistrut clamp

Universal Clamp for Ridgid/Thinwall Conduit

Model : Unistrut

Type : Standard

 

Unistrut Clamps are punch-press made and conform to ASTM specifications and are high quality system components that are designed to work with the Unistrut (R) framing system. Electro-Galvanized Zinc is deposited on part in an electroplating process. SC1 (mild) has a Zinc coating of 0.2 and is recommended for dry indoor use.