BRASS CABLE GLAND CMP 20S A2F 1/2in NPT

BRASS CMP CABLE GLAND  20S A2F 1/2″ NPT,  CABLE GLAND M20

 

cable-gland-cmp_20s-a2f

 

A2F | Ex e, Ex d, Ex nR, Ex ta | Explosive Atmosphere Cable GlandFor all types of Unarmoured & Braid Armour Cables

Globally Approved, Explosive Atmosphere Cable Gland

• Displacement type flameproof seal
• Deluge protected
• -60˚C to +130˚C (standard), -20˚C to 200˚C (ThermEx option A2FHT)
• Globally marked, IECEx, ATEX & CSA
• Class I Zone 1, Class I Division 2 BCD (Canada Only)

 

Technical
Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class B
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
ATEX Certificate SIRA13ATEX1068X
Code of Protection II 2G, II 1D Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da
II 3G Ex nR IIC Gc I M2 Ex d I Mb, Ex e I Mb
Compliance Standards EN 60079-0,1,7,15,31
IECEx Certificate IECEx SIR 13.0023X, IECEx SIM 14.0006
Code of Protection Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
Compliance Standards IEC 60079-0,1,7,15,31
CSA Certificate 1211841
Code of Protection Class I, Div 2 Groups B, C, D; Class II, Div 2 Groups E, F, G; Class III, Div 2; Type 4X: Oil Resistant II: Ex d IIC, Ex e II, Ex nR II
Compliance Standards C22.2 No 0,0.4, 94, 174, CAN/CSA-E60079-0,1,7,15
EAC Certificate (Formerly GOST R, K & B) TC RU C-GB.ГБ05.B00138
KCC Certificate 13_GA4BO_0748X, 13_GA4BO_0749X, 13_GA4BO_0750X, 14_GA4BO_0251X
NEPSI Certificate GYJ13.1140X , GYJ13.1282X
INMETRO Certificate TÜV 12.0619X
CCOE / PESO (India) Certificate P333688
RETIE Certificate 03866
Marine Approvals LRS: 01/00172 (E3), DNV: E-13848, ABS: 14-LD234401A-4-PDA
Ingress Protection Rating ** IP66, IP67 & IP68
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer
Cable Type Unarmoured & Braided when terminated inside enclosure
Sealing Technique CMP Unique Displacement Seal Concept
Sealing Area(s) Cable Outer Sheath

* Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings

 

Cable Gland Size Available Entry Threads “”C””(Alternate Metric Thread Lengths Available) Overall
Cable
Diameter
““A””
Across
Flats
““D””
Across
Corners
“”D””
Protrusion
Length “”F””
Combined Ordering Reference
(Brass Metric)
Shroud Cable
Gland
Weight
(Kgs)
Standard Option
Metric Thread Length (Metric) ““E”” NPT Thread Length
(NPT) “”E””
NPT Min Max Max Max Size Type Ordering
Suffix
16 M16 15.0 3.2 8.7 24.0 26.4 29.9 16 A2F 1RA PVC04 0.060
20S16 M20 15.0 1/2”” 19.9 3/4”” 3.2 8.7 24.0 26.4 26.0 20S16 A2F 1RA PVC04 0.070
20S M20 15.0 1/2”” 19.9 3/4”” 6.1 11.7 24.0 26.4 26.0 20S A2F 1RA PVC04 0.060
20 M20 15.0 1/2”” 19.9 3/4”” 6.5 14 27.0 29.7 27.7 20 A2F 1RA PVC05 0.070
25 M25 15.0 3/4”” 20.2 1”” 11.1 20 36.0 39.6 35.5 25 A2F 1RA PVC09 0.130
32 M32 15.0 1”” 25 1 1/4”” 17.0 26.3 41.0 45.1 35.1 32 A2F 1RA PVC10 0.150
40 M40 15.0 1 1/4”” 25.6 1 1/2”” 23.5 32.2 50.0 55.0 35.1 40 A2F 1RA PVC13 0.200
50S M50 15.0 1 1/2”” 26.1 2”” 31.0 38.2 55.0 60.5 33.0 50S A2F 1RA PVC15 0.260
50 M50 15.0 2”” 26.9 2 1/2”” 35.6 44 60.0 66.0 37.3 50 A2F 1RA PVC18 0.270
63S M63 15.0 2”” 26.9 2 1/2”” 41.5 49.9 70.5 77.6 33.5 63S A2F 1RA PVC21 0.430
63 M63 15.0 2 1/2”” 39.9 3”” 47.2 55.9 75.0 82.5 36.2 63 A2F 1RA PVC23 0.400
75S M75 15.0 2 1/2”” 39.9 3”” 54.0 61.9 84.0 92.4 34.1 75S A2F 1RA PVC24 0.520
75 M75 15.0 3”” 41.5 3 1/2”” 61.1 67.9 84.0 92.4 40.9 75 A2F 1RA PVC26 0.500
90 M90 24.0 3 1/2”” 42.8 4”” 66.6 79.9 108.0 118.8 60.3 90 A2F 1RA PVC31 1.600
100 M100 24.0 3 1/2”” 42.8 4”” 76.0 91 123.0 135.3 57.2 100 A2F 1RA LSF33 1.780
115 M115 24.0 4”” 44 5”” 86.0 97.9 133.4 146.7 67.3 115 A2F 1RA LSF34 2.670
130 M130 24.0 5”” 46.8 97.0 114.9 152.4 167.6 74.7 130 A2F 1RA LSF35 3.800
Dimensions are displayed in millimetres unless otherwise stated

 

 

 

 

 

 

 

 

CMP E1FW M32 Cable Gland

CMP CABLE GLAND

Available : CMP 32-E-FX-Z

Type: EExd IIC / EExd II BAS

Ex94c1293U  1″ – NPT
CMP Products is a leading specialist manufacturer of Cable Glands, Cable Connectors and associated accessories, used extensively for power, control, lighting and instrumentation cable applications in connection with IEC, NEC & CEC cables.

Having the widest portfolio of Cable Gland products to meet every kind of environment, CMP offers a variety of solutions for use in Marine, Explosive and Non Explosive (Industrial) Atmospheres, for a large selection of cable types.

The product search page of the website includes a number of the typical industry standard cable types found around the world that CMP cable glands can be associated with.

CMP design and produce Cable Glands with Ex d/Ex e Zone 1, Zone 2, Zone 21 & Zone 22 Approvals for use in Gas Group IIC environments under CENELEC & IEC Area Classification rules. Additionally Cable Connectors for NEC & CEC Classified Explosive Atmospheres Locations, are available for Class I, II & III, Divisions 1 & 2, where Gas Groups A, B, C, D and Dust Groups E, F & G are present.

International Explosive Atmospheres Approvals are held from Atex, IECEx, CEPEL/Inmetro, CSA, cCSAus, UL, GOST, EAC, NEPSI, TUV, and CIDET.

 

In addition Marine Classification Society Approvals from Lloyds, DNV & ABS are also held.

 

E1FW Tri-Star Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR Cable Gland

 

CMP Type E1FW Tri-Star Triple Certified Flameproof (Type “d”), Increased Safety (Type “e”) and Restricted Breathing (Type “nR”) cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Explosive Atmospheres with Single Wire Armour (SWA) cable.

All CMP Cable Glands are EMC Tested.
E1FW ILL

Note: Deluge Proof version available, ferrule colour coded “white” for ease of identification

 

E1FW Cable Gland Table

Cable Gland Size Available Entry Threads ‘C’ Minimum Thread length ‘E’ Cable Bedding Diameter ‘A’ Overall Cable Diameter ‘B’ Armour Wire Diameter Across Flats ‘D’ Across Corners ‘D’ Nominal Protrusion Length ‘F’ Ordering Reference (Brass Metric) # PVC Shroud Reference* Cable Gland Weight (Kgs)
Standard Option Min Max Min Max Min Max Max Max
Metric NPT NPT2
20S/16 M20 1/2″ 3/4″ 15.0 3.1 8.6 6.1 13.2 0.80 1.25 24.0 26.4 58.5 20S16E1FW1RA PVC04 0.157
20S M20 1/2″ 3/4″ 15.0 6.1 11.6 9.5 15.9 0.80 1.25 24.0 26.4 58.5 20SE1FW1RA PVC04 0.157
20 M20 1/2″ 3/4″ 15.0 6.5 13.9 12.5 20.9 0.80 1.25 30.5 33.6 60.5 20E1FW1RA PVC06 0.206
25S M25 3/4″ 1″ 15.0 11.1 19.9 14.0 22.0 1.25 1.60 37.5 41.3 67.5 25SE1FW1RA PVC09 0.325
25 M25 3/4″ 1″ 15.0 11.1 19.9 18.2 26.2 1.25 1.60 37.5 41.3 67.5 25E1FW1RA PVC09 0.325
32 M32 1″ 1-1/4″ 15.0 17.0 26.2 23.7 33.9 1.60 2.00 46.0 50.6 69.5 32E1FW1RA PVC11 0.452
40 M40 1-1/4″ 1-1/2″ 15.0 22.0 32.1 27.9 40.4 1.60 2.00 55.0 60.5 78.0 40E1FW1RA PVC15 0.657
50S M50 1-1/2″ 2″ 15.0 29.5 38.1 35.2 46.7 2.00 2.50 60.0 66.0 75.5 50SE1FW1RA PVC18 0.734
50 M50 2″ 2-1/2″ 15.0 35.6 44.0 40.4 53.1 2.00 2.50 70.0 77.0 80.5 50E1FW1RA PVC21 0.748
63S M63 2″ 2-1/2″ 15.0 40.1 49.9 45.6 59.4 2.00 2.50 75.0 82.5 91.5 63SE1FW1RA PVC23 1.337
63 M63 2-1/2″ 3″ 15.0 47.2 55.9 54.6 65.9 2.00 2.50 80.0 88.0 92.0 63E1FW1RA PVC25 1.436
75S M75 2-1/2″ 3″ 15.0 52.8 61.9 59.0 72.1 2.00 2.50 89.0 97.9 99.0 75SE1FW1RA PVC28 2.073
75 M75 3″ 3-1/2″ 15.0 59.1 67.9 66.7 78.5 2.50 3.00 99.0 108.9 102.0 75E1FW1RA PVC30 2.622
90 M90 3″ 4″ 24.0 66.6 79.9 76.2 90.4 3.15 4.00 114.0 125.4 120.0 90E1FW1RA PVC32 4.174
100 M100 4″ 5″ 24.0 76.0 90.9 86.1 101.5 3.15 4.00 123.0 135.3 148.0 100E1FW1RA LSF33 4.523
115 M115 4″ 5″ 24.0 86.0 97.9 101.5 110.3 3.15 4.00 133.4 146.7 169.0 115E1FW1RA LSF34 6.860
130 M130 5″ 6″ 24.0 97.0 114.9 114.2 123.3 3.15 4.00 146.1 160.7 183.0 130E1FW1RA LSF35 8.121
Dimensions are displayed in millimetres unless otherwise stated

NOTE: *CMP SOLO LSF Halogen Free Shrouds also available on request. + Alternative armour clamping range available for non-standard armour sizes. # Other thread forms, materials and finishes are available. IEC Ex, ATEX & CSAus Explosive Atmosphere certification marking included as standard.

# IP66 as standard, IP67/IP68 available on request. Deluge Proof when fitted with optional CMP O-ring in the cable gland body joint.

Note: Ingress Protection and Deluge Protection are essentially different and should not be confused with each other.

Technical Data
Type E1FW Tri-Star
Design Specification EN 50262, BS 6121: Part 1:1989, IEC 62444
Mechanical Classifications Impact = Level 8, retention = Class B (EN 50262) Class D (IEC 62444)
Electrical Classifications Category B
ATEX Certificate SIRA13ATEX1071X, SIRA13ATEX4077X
Code of Protection Ex II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da, Ex II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb
Compliance Standards EN 60079-0,1,7,15,31
IEC Ex Certificate IECEx SIR 13.0026X
Code of Protection Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
Compliance Standards IEC 60079-0,1,7,15,31
cCSAus Certificate 1310517
Code of Protection Ex d IIC; Ex e II; Ex nR II; Class I, Div 2, Groups A,B,C,D; Class II, Div 2 Groups E,F,G; Class III; Encl Type T4X Class I, Zone 1, AEx e II / AEx nR II
Compliance Standards CAN/CSA-C22.2 No 0,18,25,30,174,94, CAN/CSA-E60079-0,1,7; ANSI/UL 514B Ed 5; ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4; UL60079-0,1,7
EAC Certificate (Previously GOST R & GOST K) TC RU C-GB.ГБ.05.B.00138
Code of Protection Ex 1 Ex d IIC Gb X, 1 Ex e IIC Gb X, 2 Ex nR IIC Gc X, Ex ta IIIC Da X
NEPSI Certificate GYJ13.1140X
Code of Protection Ex d IIC Gb / Ex e IIC Gb / DIP A21 TA
Compliance Standards GB3836.1/2/3, GB12476.1
INMETRO Approval TÜV 12.0618X
Code of Protection Exd II C Gb / Exe II C Gb, IP66W
Compliance Standards ABNT NBR IEC 60079-0,1,7 ANBT NBR IEC 60529:2005
RETIE Approval No. 03866
Marine Approvals LRS: 01/00172, DNV: E-10496, ABS: 01-LD234401A/3-PDA, RMRS: 011-6.11.4-5149
Continuous Operating Temperature -60°C to +130°C, (-20°C to +200°C with optional high temperature seal)
Ingress Protection Rating IP66 (Standard), IP67 & IP68 option available on request
Deluge Protection DTS01:91 option available on request
EMC Test Information SGS report 444 to EN55022
Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal Material CMP SOLO LSF Thermoset Elastomer
Cable Type(s) Single Wire Armour (SWA), Aluminium Wire Armour (AWA)
Armour Clamping Detachable Armour Cone & AnyWay Universal Clamping Ring
Sealing Technique CMP Inner Displacement Seal & Unique CMP “LRS” TM Outer Load Retention Seal
Sealing Area(s) Cable Inner Bedding & Outer Cable Sheath
Accessories Adaptor/Reducer, Earth Tag, Locknut, Serrated Washer, Entry Thread Seal, Shroud